SECURE INTRANET & BRANCH CONNECTIVITY / MALAYSIA

Many branches.
One connected business.

Bring your branch offices, shops and warehouses back to headquarters through a secure enterprise intranet. We design and deploy hub-and-spoke networks so your teams can reach the business systems they need.

See how it connects

Based in Johor. Welcoming projects across Malaysia.

HUB & SPOKEIllustrative topology
Branch 01Retail
Branch 02Office
Branch 03Warehouse
Branch 04Service site
HQHeadquartersCentral hub
Shared systems · Files · Internal applications
Four example branches connect to the HQ gateway through encrypted IPsec tunnels. Access follows routing and firewall policies. Backup links are omitted for clarity.
YOUR SITES, WORKING TOGETHER

A private path
back to headquarters.

An intranet connects your organisation’s internal systems and users. With a hub-and-spoke design, each branch is a spoke and the HQ gateway is the hub.

The physical connection can be an internet service, with IPsec tunnels protecting traffic between sites. Your teams gain controlled access to shared resources while each site keeps its own local network.

  1. 01

    Start at the branch

    A user opens an approved business system, such as an ERP, inventory application or file service hosted at HQ.

  2. 02

    Connect through the hub

    The branch gateway sends the traffic through its tunnel to HQ. Routing and firewall rules determine the permitted destination.

  3. 03

    Reach the right systems

    Users access the services they need. Branch-to-branch access is enabled only where required; in the basic model, it also passes through HQ.

BUILT AROUND YOUR REQUIREMENTS

Connect your sites.
Choose how to manage them.

Start with your applications, site count and available connections. We select the approach around your existing environment and plans for growth.

CONNECT YOUR LOCATIONS

Site-to-site IPsec VPN

Build encrypted tunnels between branch gateways and HQ over suitable internet connections. A practical starting point when your main requirement is access to central business systems.

  • Branch-to-HQ tunnels and routing
  • Firewall rules for approved applications
  • Device, ISP and VPN compatibility review
MANAGE MULTIPLE CONNECTIONS

SD-WAN with IPsec overlays

Combine site connectivity with link health checks and traffic policies. Select paths for business applications across available WAN links, according to the chosen platform and design.

  • Application-aware path selection where supported
  • Primary and backup WAN policies
  • Central visibility across participating sites

Adding another branch?

Extend the agreed design with site addressing, gateway configuration, access rules and validation. If your traffic grows beyond HQ, we can assess a second hub, cloud connectivity or supported direct branch paths.

PLAN THE WHOLE CONNECTION

More than
a tunnel between sites.

A useful intranet needs predictable routes, clear access rules and a recovery plan. These are part of the design conversation from the beginning.

Explore your data centre network
Addressing & routing
Plan distinct subnets for each site and routes to shared services. Review overlapping IP ranges, DNS and return paths before connecting existing networks.
Access & segmentation
Separate staff, guest Wi-Fi and operational device networks. Define which sites and users may reach each HQ application, and whether branches may communicate with one another.
Internet & cloud access
Choose which traffic returns to HQ and which uses a protected local internet exit. Include private cloud or colocation access where your systems require it.
Backup connections
Consider a second ISP or suitable 4G/5G connection, redundant gateways and an alternative hub. Size backup capacity and test how the applications recover when a path fails.
FROM DESIGN TO HANDOVER

One branch first.
A plan for the rest.

Whether you need a design review, gateway configuration or a rollout across multiple locations, we agree the deliverables before deployment.

  1. 01

    Map your sites

    Review locations, ISPs, gateways, IP ranges, applications and access requirements.

  2. 02

    Agree the design

    Define topology, security policies, equipment, licences, backup paths and acceptance checks.

  3. 03

    Deploy & validate

    Pilot a branch, then roll out in agreed stages. Test application access, isolation and failover.

  4. 04

    Document & support

    Hand over agreed diagrams, configuration backups and operating notes. Define ongoing monitoring and support.

BEFORE WE CONNECT YOUR SITES

Your network.
Your questions.

Do all branches need to use the same IP subnet?

No. A routed intranet normally uses a different subnet at each site. Routing and firewall policies provide access to shared systems. Reusing the same subnet at different branches can create conflicts; we review the address plan and any migration or translation requirements.

Must every internet connection go through HQ?

No. Internal application traffic can return to HQ while internet and cloud traffic use a secured local exit. Alternatively, selected traffic can use central inspection at HQ. The choice depends on your security policy, applications and available capacity.

Can one branch connect to another?

Yes, when permitted by the design. In a basic hub-and-spoke network, that traffic passes through the hub. Direct branch-to-branch paths can be considered where the platform supports them and your traffic requirements justify them.

Can you use our existing routers and firewalls?

We review the models, firmware, licences and capacity first. IPsec connectivity between different vendors may be possible with compatible settings. Central SD-WAN management and advanced features depend on the selected platform and are not automatically shared across different brands.

What happens if an ISP or the HQ connection fails?

A single hub or WAN link can become a point of failure. Depending on your requirements, the design can include backup links, redundant gateways or a second hub. Failover must be configured and tested; sessions may reconnect, and recovery depends on the applications, providers and available backup capacity.

LET’S TALK ABOUT YOUR REQUIREMENTS

Let’s connect your branches to HQ.

Tell us how many sites you have, where your systems run and what your teams need to access. We’ll help define your network and the next step.

WhatsApp 018-6667841
PREFER EMAIL?sales@rjglobalnetworks.com

Based in Muar, Johor.
Welcoming projects across Malaysia.

Office & company details
LET’S CONNECT

Tell us what’s next.

Create a short project brief to save and share with our team.